Whole-building energy & flexibility analysis · International Energy Agency & BIT
No weather Ready

01 / Location and weather

Location and weather

Search for a city or enter coordinates, then fetch a year of hourly weather from NASA POWER for that location.

Type at least two letters; use the arrow keys or Tab to reach the matches. Place names from Open-Meteo geocoding.

02 / Geometry

Building geometry

Choose a footprint mode. Floor area, roof area, wall area and volume are auto-computed from wall and envelope dimensions.

Geometry mode

Simple box

North is 0 degrees, east is 90, south is 180, and west is 270.
Total wall area: 0 m²  ·  Footprint: 0 m²  ·  Floor area: 0 m²

Manual wall-by-wall definition

Required: at least 4 walls, 1 roof, and 1 floor

Building proportions & defaults

Wall heights use the storey count and floor height by default. You can customize each wall below.

Walls (4)

With Auto-link enabled, changing any wall's azimuth rotates the remaining walls by the same amount. Supports polygons with four or more walls. Adjusting wall lengths auto-sizes floor and roof elements from the polygon area.

Total wall area: 0 m²

Roof (1)

Roof elements auto-update from wall dimensions. A flat roof uses 0 degrees and a vertical surface uses 90 degrees.

Total roof area: 0 m²

Floor (1)

Ground floor slab elements auto-update from wall dimensions.

Total ground floor area: 0 m²
Conditioned floor area (ground floor × storeys): 0 m²

Building footprint & solar compass preview

Real-time geometry & orientation layout
Walls (N/E/S/W vectors & normals)
Floor & Roof footprint hub
Cardinal solar azimuth (0° N, 90° E, 180° S, 270° W)

03 / Openings and glazing

Openings & glazing

Specify windows, doors, glazing properties, shading geometries (overhangs, side obstructions, blinds), and frame fractions.

Visual variable reference guide and diagrams

Allocation mode

Automatic glazing & door allocation

Used to determine solar glazing area; whole-window U already includes the frame
Used when overhang shading is selected
horizon obstruction e.g. adjacent buildings, trees (0–89°)
Optional transmitted fraction when no shading type is selected
Total wall area: 0 m²  ·  Total gross window area: 0 m²

04 / Envelope and construction

Envelope & construction

Define opaque thermal layers, U-values, solar absorptance, shading of the opaque surfaces, and thermal mass for all walls, the roof and the floor.

Effective heat capacity = class × floor area (ISO 13790:2008 Table 12).
Coupled floor boundary temperature
Natural air infiltration rate
Examples: grass or asphalt 0.20; light concrete 0.40; snow 0.70

05 / HVAC and systems

HVAC performance presets

Choose a screening preset or enter seasonal heating efficiency and cooling COP. Presets do not model equipment capacity, dispatch, or part-load behavior.

Seasonal performance assumptions

Air-Source Heat Pump with high seasonal COP
Split system or VRF with seasonal cooling EER / COP
Set from the heating preset; change it if your system differs. Used for energy costs and the electricity balance.
All cooling presets run on electricity.
Thermal conversion efficiency or seasonal COP (can exceed 1.0 for heat pumps)
Seasonal operating COP / EER of cooling equipment
Target maximum indoor relative humidity (%)

06 / Internal gains and setpoints

Internal gains & setpoints

Setpoints, occupant loads, plug loads, lighting power, and specialized electrical and thermal end-uses.

May be fractional, e.g. 2.5 for a household often out. Sensible gain 75 W per person.
Breathing, cooking, washing and drying. Auto uses 125 g/h per occupant (BS 5250 / IEA Annex 14: about 5–7 kg a day for two people).

Plug, lighting & base equipment loads

Interior lighting energy
General electronics and standard plug loads
Circulation pumps, ventilation fans, distribution

Specialized building equipment & process gains

Continuous IT racks, UPS, network closets
Domestic or commercial kitchen sensible emissions
Mechanical transport, lifts, variable motors
Lighting: 0 W  ·  Base Equipment: 0 W  ·  Aux/Fans: 0 W  ·  Total Sensible Heat Gains: 0 W

Annual HVAC screening adjustments

These factors scale reported annual HVAC demand. They do not create hourly schedules, unoccupied temperature drift, recovery loads, or separate room zones.

Post-calculation multiplier for screening only
Post-calculation multiplier for screening only
Scales demand but does not model separate room conditions

07 / Energy management and renewables

Energy management and renewables

Optional. Switch on the parts that apply to this building. With every card switched off the results are the same as without this step.

Grid peak window

The hours when grid electricity is most expensive or most constrained, usually the early evening. Load shifting, battery peak shaving and time-of-use operation, and off-peak EV charging all use this window.

16 to 20 means 16:00 until 20:00.

Building controls (BEMS)

A building energy management system changes the heating and cooling setpoints by the hour. Helios simulates the building without these controls and with them (plus a few extra runs to find the smallest plant that still keeps the rooms comfortable) and reports the difference in plant size, the busiest grid hour, energy, cost and comfort. The results card explains each number in plain words.

Rooftop solar PV

Photovoltaic panels on the main roof. Generation is simulated hour by hour from the weather file's solar radiation and air temperature.

Battery storage

A home or building battery that stores electricity and releases it later.

Electric vehicle

Electric cars charged at the building. Charging is added to the building's electricity demand.

Tariff

Energy prices used for the annual cost and the cost change from demand-side management. Enter your own supplier's prices.

08 / Run and results

Run & results

Execute the hourly simulation model with the fetched NASA POWER weather dataset.

Idle
No calculated result for the current inputs.

Export & share scenario run

The complete run bundle packages all scenario inputs, controls, tariffs, hourly weather metadata, and verified simulation outputs into a single JSON file. Colleague analysts can upload this bundle to inspect the exact scenario state and all resulting metrics without rerunning.